STAT Low-Profile Air Strippers
Our patented, high performance air stripper


STAT low profile air stripperCarbonair's patented STAT series of low profile air strippers combine high performance (99.99% or greater removal efficiency of VOCs), flexibility, and design simplicity. With multiple tray configurations, blower options, controls, and instrumentation, each STAT air stripper can be customized to meet your site requirements. With flows ranging from less than one gallon per minute up to 1000 gpm, Carbonair has an air stripper to fit your needs.

Click here to go to our Contact Us page and request a copy of our STAT Modeling software.


STAT Low Profile Air Stripper Specifications

Models>

STAT 15 STAT 30 STAT 80 STAT 180 STAT 400 STAT 720
Tray Dimensions 24"L x 10"W x 10"H 36"L x 14"W x 10"H 48"L x 24"W x 10"H 72"L x 36"W x 12"H 120"L x 48"W x 12"H 144"L x 72"W x 12"H
Sump Capacity 16 gallons 30 gallons 60 gallons 225 gallons 500 gallons 1000 gallons
Max. Height 7'-7" 7'-10" 7'-10" 9'-6" 10'-2" 11'-0"
Water Flow Range (gpm) 0.5 - 15 1 - 40 5 - 100 10 - 200 20 - 400 40 - 1000
Air Flow (cfm) 80 150 350 900 2,100 3,500
Skid Dimensions 48"L x 30"W x 6"H 64"L x 34"W x 6"H 66"L x 66"W x 6"H 88"L x 86"W x 6"H 136"L x 98"W x 6"H Call for sizing
Standard Features
  • 304 stainless steel construction
  • Polypropylene demister material capable of removing 95% of droplets 5 microns or larger
  • Flanged (125 pound) inlet and outlet configuration to maximize the integrity of piping connections
  • Anti-Bypass valve* eliminates need for priming prior to system start-up, ensuring that the first gallon to enter the unit will be treated as well as the last gallon
  • Flapper valve* (Gravity units) prevents air from bypassing the sieve trays through the water effluent port
  • Weir type square downcomer flow distribution system ensures uniform water distribution over the trays
  • Tray fastened by over-center latching stainless steel clips
  • Collection sump minimizes pump cycling requirements and maintains sufficient turbulence
  • Low pressure switch mounted in the blower discharge piping to shut down unit in the event of blower failure
  • Direct coupled blower to maintain high pressure air at low flow rates

 Optional Components
  • Air temperature gauges
  • Air Flow meters
  • Water temperature gauges
  • Water flow meters
  • Discharge pump with level controls
  • Sample ports
  • Explosion-proof controls
Click here to download a copy of our STAT Series Specification Sheet.

*Protected under U.S. Patent Numbers 5,478,507 and 5,378,378.
STAT is a registered trademark of Carbonair Environmental Systems, Inc.
   